See the well take shape.
Paste survey stations, review the 3D trajectory, and share a branded preview.
Open 3D Well DesignThe 3D well design workspace leads. Every other destination is listed below.
Paste survey stations, review the 3D trajectory, and share a branded preview.
Open 3D Well DesignChoose a tool, enter the field data it asks for, then save, print or share the result from that page.
Add hole intervals and string components to see capacities, displacement, annular volume and circulation path.
Build a volume model → 3D Well Design & TrajectoryPaste survey rows, confirm depth units, load the model, rotate the drawing and share its branded preview.
Draw a well → Mud Lab TestsSelect the fluid family and test to see equipment, sample preparation, procedure, readings and common errors.
Choose a test → BOP Tests & RecordsOpen the event type, use the on-page recording steps, and enter actual results from the approved program.
Open BOP records → Mud CalculatorsChoose a calculation, select its units and enter measured starting values to get a clear result.
Open mud calculators → Field SheetsOpen the Kill Sheet or Trip Tank Sheet, enter job data and print or save the completed sheet.
Open field sheets → HSE ChecklistsChoose a rig component, lifting or general rig checklist, then complete and print the working copy.
Choose a checklist → Hydraulics RunOpen the separate Hydraulics Studio workspace to enter a run case and review its comparison tools.
Open Hydraulics Run → Study CenterFilter P&P, IWCF, WellSharp, Mud School and interview cards by set or topic; reveal answers on each card.
Study your cards → Field referencesOpen the standards and manuals directory for the source that governs a method or equipment record.
Open references →Choose a focused rig checklist, enter the actual observations, then save a local draft, download the record or print a clean sheet.
14 CHECKLISTSSources appear on each printable checklist.
Use one catalog for rig-system inspections, BOP events and well-control equipment. Open a record to see specific items, capture actual observations and evidence, and assign follow-up.
Each record captures equipment identity, check-by-check observations, evidence references and follow-up ownership. The approved rig procedure supplies its inspection steps and limits.
Function and pressure-test event records, installed stack components, control systems, manifolds, diverters and RCDs. Open a card for the specific record fields and checklist prompts.
Hoisting, mud systems, instruments, service interfaces and well-test records.
Enter the tank’s internal dimensions and measured liquid level, or paste the approved rig calibration chart for an irregular tank.
Use inside dimensions from an approved drawing or safe measurement. Do not enter a tank to measure it. Hoppers, sloped floors, baffles and fittings change usable volume; use the rig calibration chart for irregular tanks.
Record the tank ID and compartment.
Use the approved drawing or safe method.
Use the rig gauge and chart datum.
Compare it with the rig chart and record the method.
Rectangular capacity uses inside length × width × height. Vertical cylinders use circular area × height. Horizontal cylinders use the circular segment area up to the measured level. Results are converted to oilfield barrels using 42 U.S. gallons per barrel.
Geometric results are ideal estimates and do not subtract internal obstructions or dead volume. Use the rig chart for operational volume records.
Choose a fluid family and test. Open a card for its equipment-specific procedure, readings and common mistakes.
Choose a calculation, enter measured values and actual product properties, then copy or save a clear result. These calculators do not open the Mud Engineer app.
Each tool shows its units, equation and assumptions with the result.
Move the slider to preview the volume split and ideal blended weight.
Ideal volume-weighted density estimate. Real compatibility, contraction/expansion, solids and losses are not represented.
Choose a salt and select an exact table row. Each slider position selects an exact source row; displayed values come directly from the table.
Search density, salinity or chloride.
| Density ppg | Salt lb/bbl | Water bbl/bbl | Salt wt% | Cation mg/L | Cl mg/L | TCT °F |
|---|
These pump and annular-flow calculators run here. Enter the measured pump setup, pipe dimensions and actual mud properties.
Tap a card to open its input form. Results are local and shareable.
Enter measured-depth sections and string components. See each capacity and volume, with mud moving down the string and returning up the annulus in the 3D view.
Blue flows surface-to-bit inside the string. Amber returns bit-to-surface through the annulus.
Paste a spreadsheet or import a CSV to fill bore and string rows together.
path,name,type,top_md_ft,bottom_md_ft. Bore rows also use id_in; string rows use od_in,id_in. Optional: tvd_top_ft,tvd_bottom_ft,oem_internal_bbl,oem_displacement_bbl,notes,units. Use path values bore or string. Columns use field units by default; set units to metric on a row to enter m, mm and m³.Enter measured-depth intervals and actual inside diameter. TVD is recorded separately and never used for volume length.
| Section name | Type | Top MD (ft) | Bottom MD (ft) | Top TVD (ft) | Bottom TVD (ft) | Actual ID (in) | Source / notes | Row actions |
|---|
MD/path length is used for volumes. Use actual casing or liner ID. Record a caliper source or measured hole basis in notes; no washout factor is assumed.
Enter each component’s measured-depth interval, OD, and actual ID or a documented tool volume.
| Component | Class | Top MD (ft) | Bottom MD (ft) | OD (in) | ID (in) | OEM internal volume (bbl) | OEM displacement (bbl) | Source / notes | Row actions |
|---|
Internal capacity, external-envelope volume, calculated metal displacement and OEM displacement stay as separate report values. Enter OEM data for non-cylindrical tools.
Estimate the MD span for a known fluid volume along the entered internal or annular path.
Capacity and volume by interval, with cumulative depth and path totals.
Capacity (bbl/ft) = ID² ÷ 1029.4
Annular capacity (bbl/ft) = (bore ID² − string OD²) ÷ 1029.4
Metal displacement (bbl/ft) = (OD² − ID²) ÷ 1029.4
Capacity (L/m) = ID² ÷ 1273.24
Annular capacity (L/m) = (bore ID² − string OD²) ÷ 1273.24
Metal displacement (L/m) = (OD² − ID²) ÷ 1273.24
10 in ID × 1,029.4 ft = 100 bbl
10 in bore around 6 in OD × 1,029.4 ft = 64 bbl
6 in OD / 4 in ID × 1,029.4 ft = 20 bbl metal displacement
1,000 mm ID × 1 m ≈ 785.40 L
Volumes use MD/path length. TVD is a separate reference. OEM overrides are identified in the tally. These reference cases show the equations; they do not validate a particular well model or entered dimensions.
Paste or import a directional survey to draw, rotate and share a 3D well trajectory. Keep telemetry events, LWD readings and BHA records alongside the model.
Keep the source, units and station rows together here. Open the 3D Well Design & Trajectory when you want to rotate or share the trajectory.
Enter one row per station. The preview is built from these measured depths, inclinations and azimuths.
| Station | MD | Inclination ° | Azimuth ° | Comment |
|---|
Use the survey rows above to build this view. Drag to rotate, zoom to inspect, and check red intervals against your selected dogleg threshold.
Rotate the well path, review the selected dogleg highlight, and share a branded preview of the loaded survey.
Record the source reading and the context reported by the service team. Record event time, depth, signal, reported value and source context.
| Time | MD | Event | Signal / channel | Reported value | Unit | Quality / status | Context / notes |
|---|
Enter readings as reported with channel name, unit, depth/time and the quality flag supplied by the service.
| Time | MD | Measurement / channel | Reading | Unit | Quality flag | Tool / source | Notes |
|---|
Record the planned or as-run component sequence and identifiers. Use the approved tally and service documents as the source.
| Order | Component | Manufacturer / model | Serial / ID | OD / connection | Length / unit | Position / notes |
|---|
Print the Kill Sheet or Trip Tank Sheet, or choose an HSE checklist by activity and equipment group.
Choose a printable inspection record by task or equipment. Each checklist has observation fields, source references, local save, JSON download and print controls.
Record the values from the well-specific kill sheet, note its program revision, and route the entries for supervisor review.
Record expected and measured volumes by time or stand, with one row for each operation.
| # | Time / stand | Operation / notes | Expected volume | Measured volume | Unit | Initials |
|---|
Use the separate PC page to review a case and compare its component losses with a trusted reference example.
Use a case export, check field units, geometry intervals and survey stations against the source.
Load the JSON, enter choke-line loss, select the correction option, then run the test-only model.
Compare each pressure component and assumption separately. Compare each pressure component and model assumption against a reference case with known inputs and results.
IWCF Practice includes your supplied Level 4 · Surface cards alongside the original IWCF practice cards. WellSharp, Mud School and interview cards are here too. Filter by set or topic, then reveal each answer and any available note.
The catalog summarizes common test families and rig systems. The controlling procedure is the current licensed standard, operator program, local regulation, and equipment manufacturer manual.
API RP 13B-1 is the 5th edition (2019); the API 2025 catalog lists errata through January 2023. API RP 13B-2 is the 6th edition (July 2023) for nonaqueous-based field testing. API RP 13J is the 6th edition (January 2023) for water-based fluid testing. Check the official API catalog for current addenda and method scope.
Open the source document for its applicable scope, test procedure and acceptance criteria.
Use the current directional program and service-provider documentation for survey, MWD and LWD interpretation.
We found manuals for the Fann Model 35 viscometer, Model 140 mud balance, Marsh funnel, 50 mL oil/water retort, HPHT filter press and chemical analysis; and OFITE pressurized mud balance, Model 800 viscometer, electrical stability meter, API/HTHP filter presses, chloride, alkalinity, hardness, potassium, sand, MBT and water-analysis kits. Use the manual matching the equipment model on the rig and check its revision.